
- #Tutorial skm ptw full#
- #Tutorial skm ptw software#
You can use the Plan tab to configure display options that are specific to office layout diagrams. For example, when you open the Office Layout template, a Plan tab appears. Some templates have unique features that you can find on special tabs in the ribbon. Templates come ready with appropriate settings for the drawing type. For example, the Site Plan template opens with an engineering scale, where 1 inch represents 10 feet. The Organization Chart template includes distinct shapes for executives, managers, assistants, positions, consultants, vacancies, and more.Īppropriate grid size and ruler measurements
#Tutorial skm ptw full#
The Home Plan template, for example, opens with stencils full of shapes such as walls, furniture, appliances, cabinets, and so on.
Option to check upstream protective devices for mis-coordination.Templates come with stencils that are full of the shapes needed to create a particular kind of drawing. Compare results from multiple project scenarios in a single table. Automatically accumulates energy from parallel contributions that clear at different times. Induction motors can be included excluded or included for a user-defined time. Allows representation of differential, zone-interlocking, photo-sensing, and other special instantaneous protection schemes. Fuses and breakers may be modeled as current limiting devices with user-defined equations. Option to report in English or Metric units. Option to perform DC Arc Flash analysis. Option to follow the NFPA 70E, IEEE 1584 or NESC standards. Full featured reporting including bus report, line-side report, and load-side report.
Report selected bus locations using custom queries or go-to function. Create custom labels in any size with user-defined logos, text, comments, field placement, and local language support. Arc Flash labels are automatically produced to comply with NEC 110.16 labeling requirements and can be printed to several standard size label sheets. Bus and branch arcing fault values are automatically calculated and trip times are automatically determined from the protective device settings. Pre-populated library of protective clothing allows user-defined PPE additions. Summary and detail view enables complete bus by bus examination of study data. Simple to use tabular interface for system design, PPE selection, and reviewing study results. Avoid potential fines, lost productivity, and increased insurance and litigation costs.
Save time by automatically generating arc flash labels and work permits.
Improve safety margins with user-definable arcing fault tolerances. Evaluate alternatives quickly and easily to establish an optimal design. Wearing inadequate clothing is dangerous for obvious reasons, but wearing too much clothing is dangerous due to limited mobility and visibility. Provide a safer working environment by specifying the proper level of clothing. Save time with the fully integrated Short Circuit, Over-Current Coordination, Equipment Evaluation and Arc Flash Evaluation modules working together with libraries of clothing levels, protective devices and bus ratings. Design safer power systems while applying NEC 110.16, NFPA 70E, IEEE 1584, and NESC (OSHA 1910.269 Appendix E) standards or requirements. Clearing times can be automatically reduced based on current-limiting capabilities. Clothing requirements are specified from a user-defined clothing library. Incident energy and arc flash boundaries are calculated following the NFPA 70E, IEEE 1584 and NESC standards. Arc Flash saves time by automatically determining trip times from the protective device settings and arcing fault current values. PTW Arc Flash Evaluation calculates the incident energy and arc flash boundary for each location in a power system.
#Tutorial skm ptw software#
provides a complete line of electrical engineering software including PowerTools for Windows and Arc Flash Hazard Analysis.